E3D commands: E3D/pdms piping modeling commands

E3D/Pdms is 3D software  which is  used for  designing oil and gas project, refineries, power plants, chemical and petrol-chemical plants. Pdms software  used for 3D designing as well as 2D for producing the  piping isometrics, piping general arrangements, equipment layout etc. E3D/Pdms has  different  module in which different  discipline can work simultaneous like piping modeling , equipment modeling, structure modeling, Draft, Isodraft, Multi discipline piping supports, Cable modeling 

These below mentions are the pdms  modeling commands which are used in Aveva Pdms 12.1. Pdms command are used while  do the modeling  in pdms software. Pmds software is based on commands  based  as well as  graphics based. With the help of  these pdms command, its easy to  do the piping modeling, equipment modeling, structure modeling in the 3D  pdms model. These are below mention PDMS command  helps to  speed up work on pdms model. 
 
S.NO.  PDMS COMMAND EXPANSION OF COMMAND
1 DELETE BRAN DELETE BRANCH
2 Q HSTU TO DISPLAY BRANCH HEAD SIDE TUBE ATTRIBUTES
3 Q LSTU TO DISPLAY COMPONENT LEAVE SIDE TUBE ATTRIBUTES
4 Q ABORE TO DISPLAY ARRIVE BORE OF A COMPONENT
5 Q LBORE TO DISPLAY LEAVE SIDE BORE OF A COMPONENT
6 ADD HREF TREF ADD HEAD & TAIL REFERENCE
7 Q HBORE TO DISPLAY THE HEAD SIDE BORE OF A BRANCH
8 Q TBORE TO DISPLAY THE TAIL SIDE BORE OF A BRANCH
9 Q SPRE TO DISPLAY THE SPECIFICATION OF THE COMPONENT
10 Q PSPEC TO DISPLAY THE SPECIFICATION OF THE PIPE
11 NEW ELBO CHOO CREATE NEW ELBO
12 NEW ELBO SEL WITH STYP EA TO CREATE THE ELBO WITH SPECIFIC SELECTION TYPE
13 AXES AT HPOS AXES AT HEAD POSSITION OF THE BRANCH
14 AXES AT TPOS AXES AT TAIL POSSITION OF THE BRANCH
15 NEX TUBI ASKING FOR TUBE BEING ON THE COMPONENT
16 Q ITLE TO DISPLAY THE LENGTH OF THE TUBE BETWEEN TWO COMPONENTS
17 Q HREF TO DISPLAY THE HEAD REFERENCE OF A BRANCH
18 Q TREF TO DISPLAY THE TAIL REFERENCE OF A BRANCH
19 Q DIR TO DISPLAY THE DIRECTION OF THE SELECTED COMPONENT
20 CONN PH TO FIR MEM CONNECT BRANCH HEAD TO THE FIRST MEMBER OF THE BRANCH
21 CONN PT TO LAS MEM CONNECT THE BRANCH TAIL TO THE LAST MEMBER OF THE BRANCH
22 Q ORI TO DISPLAY THE ORIENTATION OF SELECTED COMPONENT
23 DIST GIVING THE DISTANCE BETWEEN TWO COMPONENT CENTERS
24 CLEA (SPOOL) GIVING THE SPOOL DISTANCE BETWEEN TWO COMPONENTS
25 Q CATREF TO DISPLAY THE CATALOGUE REFERENCE AT COMPONENT LEVEL
26 CONN CONNECT
27 FCONN FORCE CONNECT
28 Q STYP TO DISPLAY THE COMPONENT SELECTION TYPE
29 Q DTXR TO DISPLAY THE DETAIL TEXT(DESCRIPTION OF THE COMPONENT
30 DRAG BY E 1000 STRECH THE COMPONENT BY EAST 1000 (NOT PREFERED)
31 Q MTXX TO DISPLAY THE MATERIAL OF THE COMPONENT
32 Q MODE TO DISPLAY THE MODE OF DIRECTION (FOR/BACK)
33 FOR TO SET THE FORWARD MODE
34 BACK TO SET THE BACKWARD MODE
35 FIRST MEM TO NAVIGATE THE FIRST MEMBER
36 LAST MEM TO NAVIGATE THE LAST MEMBER
37 FIRST FLAN TO NAVIGATE THE FIRST FLANGE IN HIERARCHY
38 Q PARA TO DISPLAY THE PARAMETERS
39 Q ACONN TO DISPLAY THE ARRIVE CONNECTION DETAIL OF A COMPONENT
40 Q LCONN TO DISPLAY THE LEAVE CONNECTION DETAILS OF A COMPONENT
41 DIR TOW NEX DIRECTION TOWARDS THE NEXT COMPONENT
42 Q REF TO DISPLAY REFERENCE
43 INCL INCLUDE
44 ORI AND P3 IS UP ORIENT P3 OF TEE TO UP (SPECIFIED DIRECTION)
45 OWN NAVIGATE OWNER
46 GOTO OWN GO TO OWNER OF THE SELECTED COMPONENT
47 Q ABOP/LBOP DETAILS OF THE ARRIVE/LEAVE BOPTOM OF PIPE
48 Q ANGLE DETAILS OF A ANGLE OF AN ELBO
49 Q ATLE LENGTH OF FIRST TUBE OF A BRANCH
50 ATTYPE CCNN COMMENT ATTACHMENT WITHOUT DIMENSION
51 ATTYPE CCCC COMMENT ATTACHMENT WITH DIMENSION
52 ATTYPE XXXX ATTA FOR SETTING THE ISOMETRIC LIMIT
53 CH CE CHECK CURRENT ELEMENT (FOR CONSISTENCY CHECK)
54 DIR  TOW NEXT ELBO ALIGN A ELBO WITH THE NEXT ELBO
55 DIR TOW ID@ ALIGN THE ELBOW
56 EXTEND 100 START/END EXTEND BY 100 THE START/END OF A CROSS MEMBER
57 Q HCON/TCON DETAILS OF HEAD/TAIL CONNECTION OF A BRANCH
58 Q HDIR DIRECTION OF THE FLOW FROM THE BRANCH HEAD
59 Q HPOS/TPOS DETAILS OF HEAD/TAIL POSSITION OF A BRANCH
60 Q ISPE INSULATION SPECIFICATION
61 ISPEC NULREF FOR REMOVING INSULATION
62 SPKBRK T FOR REMOVING INSULATION (USE IN CASE FOF ATTA)
63 LOOSE USED BY ISODRAFT WHERE THE FLANGE IS SUPPLIED LOOSE
64 MTOC DOTD MTO COMPONENT DOTTED WITH DIMENSION
65 MTOC DOTU MTO COMPONENT DOTTED WITH OUT DIMENSION
66 MTOC OFF MTO COMPONENT OFF
67 NEX CONN NEXT CONNECT
68 NEX THRO CE MOVE THE CURRENT COMPONET TO NEXT
69 ORI AND P3 IS TOW ID ALIGNING THE 3RD P-POINT OF A TEE TOWARDS NEXT ELBOW

@& DIR TOW ID@
70 Q P3 DETAILS OF P-POINT P3 (IN CASE OF TEE ONLY)
71 Q PA/P1 DETAILS OF THE P-POINT 1
72 Q PL DERAILS OF THE P-POINT 2
73 STEXT 'TEXT' SETTING THE COMMENT TEXT
74 TCONN OPEN TAIL CONNECTION TYPE OPEN (CE SHOULD BE BRANCH)
75 TDIR DIRECTION OF THE FLOW FROM THE BRANCH TAIL
76 ISPEC /W TO GIVE THE INSULATION 
77 Q LBORE TO QUERY LEAVE BORE
78 Q TBORE TO QUERY THE TAIL BORE
79 THRO PH THROUGH PIPE HEAD
80 THRO PREV THROUGH PREVIOUS
81 THRO PT THROUGH PIPE TAIL
82 Q TPOS TO QUERY TAIL POSITION
83 Q HCON TO QUERY THE HEAD CONNECTION
84 Q TCON TO QUERY THE TAIL CONNECTION
85 Q ACON TO QUERY ARRIVE CONNECTION
86 Q LCON TO QUERY LEAVE CONNECTION
87 ATTYPE FLOW TO CREATE FLOW DIRECTION OF ATTACHMENT
88 DIR N  DIRECTION OF COMPONENT TOWARDS NORTH
89 BACK CONN BACKWARD CONNECTION
90 MTOC UNSET TO FREEZE THE COMPONENT FROM MTO REPORT